Heating Zones 4
Cooling Zones 2
Loading Zones 1
Total Number of Zones 7
Platen Size 5 in. x 6.5 in. (125 x 162 mm)
Maximum Substrate Size 5 in. x 5.75 in. (125 x 144 mm)
Speed Mode (Inches Per Minute) 3 to 50 in/min. (7.5 to 125 cm/min.)
Time Mode (Dwell & Travel Time) 1 sec. to 99 min. 59 sec. (per zone)
Temperature (Standard) Up to 400°C
Temperature Accuracy ± 2°C
Warm-up Time to 230°C 10 minutes
Coolant Flow 0.5 to 2 GPM (2 to 8 liters/min.)
Alarms Over/Under Temperature, Gas, Coolant, Motor Torque
Parts Flow (Specify When Ordering) L to R or R to L
Gas Consumption 120-150 cubic feet per hour
O2 Level 10 PPM, 0.25 inch opening
Voltage (Specify when Ordering) 200 to 240 VAC, 50/60 Hz, 1 or 3 Phase
Start-up Power (kW) 11kW @ 240 VAC
Power Consumption 50% or less
Basic Unit Weight 200 lbs. (91 Kg)
Basic Unit Dimensions L 53 x W 25 x H 26 inches (134.6 x 63.5 x 66 cm)
Part #      Description
7543 Software Package (Windows 98/2000/XP)
1281 “Sampling” Port to attach to Oxygen Monitor, Installed – 1 zone (O2 monitor not included)
Kit Zero Down Time Kit (2 Years Minimum Support)

Privacy Preference Center